ISSN Online: 2177-1235 | ISSN Print: 1983-5175

Showing of 1 until 20 from 53 result(s)

Search for : Silicones; Morte; Aloenxertos; Necrose; Pessoas transgênero; Contorno corporal

Use of negative pressure therapy in closed surgical incisions of post-bariatric dermolipectomy

Lara Gomes Faistel; Dilmar Francisco Leonardi
Rev. Bras. Cir. Plást. 2023;38(1):1-8 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: Negative pressure therapy gains ground in surgical practice as an intervention to improve healing. Post-bariatric patients undergoing abdominal dermolipectomy are at increased risk of local complications. There is a notable dearth of current Brazilian studies on this. This study aims to analyze the presence of complications in patients undergoing post-bariatric dermolipectomy surgery with negative pressure dressing in closed surgical incisions.
Method: Descriptive study that evaluated complications of surgical incisions in 20 patients undergoing post-bariatric dermolipectomy surgery with negative pressure therapy. Data tabulated in Windows Excel software and analyzed in the Statistical Package for the Social Sciences 18.0 program. Qualitative variables were presented in simple frequency and quantitative as mean, standard deviation, and amplitude. CEP-UNISUL approved the study.
Results: 20 patients undergoing negative pressure therapy, 80% (n=16) female, mean age 39.55 years (±9.08). Anchor incision was chosen in 70% (n=14) of the surgeries, with an average tissue removal of 1940 grams (±710.37) and hospitalization time of 40.20 hours (±19.18), corresponding to 1,66 daily. Only 15% (n=3) of patients had complications (dehiscence, seroma, and hematoma, which occurred in the same proportion). There was no case of necrosis.
Conclusion: The use of negative pressure therapy in closed surgical incisions of post-bariatric dermolipectomy seems to contribute to reducing postoperative complications.

Keywords: Negative-pressure wound therapy; Reconstructive surgical procedures; Body contouring; Obesity; Wound Healing; Seroma; Bruise; Necrosis

 

RESUMO

Introdução: Terapia de pressão negativa ganha espaço na prática cirúrgica como intervenção para melhorar cicatrização. Pacientes pós-bariátricos submetidos a dermolipectomia abdominal apresentam maior risco de complicações locais. Há uma notável escassez de estudos brasileiros atuais acerca disso. O objetivo desse estudo é analisar a presença de complicações em pacientes submetidos a cirurgia de dermolipectomia pós-bariátrica com curativo de pressão negativa em incisões cirúrgicas fechadas.
Método: Estudo descritivo que avaliou complicações de incisões cirúrgicas de 20 pacientes submetidos a cirurgia de dermolipectomia pós-bariátrica com terapia de pressão negativa. Dados tabulados no software Windows Excel e analisados no programa Statistical Package for the Social Sciences 18.0. Variáveis qualitativas foram apresentadas em frequência simples e quantitativas através de média, desvio padrão e amplitude. O estudo foi aprovado pelo CEP-UNISUL.
Resultados: 20 pacientes submetidos a terapia de pressão negativa, sendo 80% (n=16) do sexo feminino, com idade média de 39,55 anos (±9,08). Incisão em âncora foi escolha em 70% (n=14) das cirurgias, com retirada média de tecido de 1940 gramas (±710,37) e tempo de hospitalização de 40,20 horas (±19,18), correspondendo a 1,66 diárias. Apenas 15% (n=3) dos pacientes apresentaram complicações (deiscência, seroma e hematoma, que aconteceram na mesma proporção). Não houve caso de necrose.
Conclusão: Uso da terapia de pressão negativa em incisões cirúrgicas fechadas de dermolipectomia pós-bariátrica parece contribuir na redução das complicações pós-operatórias.

Palavras-chave: Tratamento de ferimentos com pressão negativa; Procedimentos cirúrgicos reconstrutivos; Contorno corporal; Obesidade; Cicatrização; Seroma; Hematoma; Necrose

 

Ultrasound-Assisted Liposuction - 348 Cases Analyzed

Ruth Graf, André Auersvald, Rosana Cristina Costa Damasio, Luiz Roberto Reis de Araújo, Ronald Rippel, Lincoln Graça Neto, Luiz Henrique Camargo Bigarelli, Cláudio Luciano Franck
Rev. Bras. Cir. Plást. 2002;17(3):37-46 - Articles

PDF Portuguese PDF English

ABSTRACT

The authors report their experience in using ultrasound-assisted liposuction in 348 patients in the period between October 1998 and July 2001. The application of ultrasound brought additional benefits to results, such as improved skin accommodation and the treatment of difficult cases, such as, gynecomasty, dorsum and secondary liposuction. The technique was performed in three stages: super-wet infiltration (l.35:1), followed by ultrasound-assisted liposuction and conventional liposuction. The equipment used was a Lisonix 2000 generator at the setting of 5, that is, 50% of the device's power; which proved to be the setting that causes the least secondary effects, such as tissue fibrosis and seroma. This study also considers the history of ultrasound assisted liposuction and focuses on the physical aspects of ultrasound, with a review on the literature on the use of the ultrasound technique.

Keywords: Liposuction; ultrasound; body contour

 

RESUMO

Os autores mostram a experiência da utilização da lipoaspiração ultra-sônica em 348 pacientes no período de outubro de 1998 a julho de 2001. A aplicação do ultra-som trouxe benefícios adicionais aos resultados, como melhor acomodação da pele e tratamento de áreas difíceis, como ginecomastia, dorso e lipoaspiração secundária. A técnica utilizada em três estágios consistiu de infiltração super-úmida (1,35:1), seguida da lipoaspiração ultra-sônica e lipoaspiração convencional. O equipamento Lisonix 2000 foi utilizado numa amplitude de 5, ou seja, 50% da potência do aparelho, que demonstrou ser a que menor efeito secundário causa, como fibrose tecidual e seroma. São considerados no artigo o histórico da lipoaspiração ultra-sônica e um enfoque na física do ultra-som, com revisão da literatura relacionada à aplicação da técnica ultra-sônica.

Palavras-chave: Lipoaspiração; ultra-sônica; contorno corporal

 

Complications of lipoabdominoplasty without Scarpa fascia preservation versus classic abdominoplasty: a prospective blind study

JOÃO MAXIMILIANO; ANTONIO CARLOS OLIVEIRA; CIRO PAZ PORTINHO; MAURICIO FARENZENA; MATHEUS REIS; TULIO SERRANO; DIEGO DULLIUS; MARCUS VINICIUS MARTINS COLLARES
Rev. Bras. Cir. Plást. 2019;34(1):15-22 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: Abdominoplasty is among the most commonly performed surgical procedures. Seroma is the most common local complication associated with abdominoplasty, with an average incidence of 10%. The highest incidence of postoperative (PO) seroma occurs on the eleventh postoperative day (POD). Abdominal ultrasound is the method of choice for diagnosing seroma after abdominoplasty. New techniques have emerged aiming to improve aesthetic results with fewer complications, such as lipoabdominoplasty described by Saldanha. However, recent anatomical studies have questioned the need for Scarpa fascia preservation recommended in the lipoabdominoplasty technique, describing that around 90% of the abdominal lymphatic system is in the subdermal plane, while the other 10% is in a deep lymphatic system near the abdominal aponeurosis. The objective is to compare the incidence of seroma in lipoabdominoplasty without Scarpa fascia preservation to that in classic abdominoplasty.
Methods: Prospective blinded cohort in which 40 consecutive patients who underwent abdominoplasty without associated liposuction (n = 20) or lipoabdominoplasty (n = 20) at the Hospital de Clínicas of Porto Alegre between April 2016 and May 2017 were analyzed. All patients underwent abdominal wall ultrasonography on the tenth POD.
Results: The incidence of seroma was 5% (n = 1) in the classic abdominoplasty group and 10% (n = 2) in the lipoabdominoplasty group, with no statistical difference.
Conclusion: These results showed no statistically significant intergroup difference in seroma development.

Keywords: Abdominoplasty; Seroma; Lipectomy; Lipodystrophy; Body contouring.

 

RESUMO

Introdução: Abdominoplastia é um dos procedimentos cirúrgicos estéticos mais realizados. Seroma é a complicação local mais comum associada com abdominoplastia, com uma incidência média de 10%. A maior incidência de seroma pós-operatório (PO) ocorre no décimo primeiro dia PO. Ecografia abdominal é o método de escolha para o diagnóstico de seroma após abdominoplastia. Novas técnicas surgiram ao longo dos anos na tentativa de trazer melhores resultados estéticos com menos complicações, como lipoabdominoplastia descrita por Saldanha. Porém, estudos anatômicos recentes questionam a necessidade da manutenção da fáscia de Scarpa descrita na técnica de lipoabdominoplastia, descrevendo que em torno de 90% do sistema linfático abdominal está no plano subdérmico e 10% em um sistema linfático profundo justa-aponeurose abdominal. O objetivo é comparar a incidência de seroma na lipoabdominoplastia sem preservação da fáscia de Scarpa com a abdominoplastia clássica.
Métodos: Coorte prospectiva, cega na qual serão analisados 40 pacientes consecutivos que realizaram abdominoplastia sem lipoaspiração associada (n = 20) ou lipoabdominoplastia (n = 20) no Hospital de Clínicas de Porto Alegre entre abril de 2016 e maio de 2017. Todos foram submetidos à ecografia de parede abdominal no 10o dia PO.
Resultados: A incidência de seroma foi de 5% (n = 1) no grupo de abdominoplastia clássica e de 10% (n = 2) no grupo de lipoabdominoplastia, sem diferença estatística.
Conclusão: Estes resultados, neste grupo de pacientes, mostram que não houve diferença estatística entre os dois grupos.

Palavras-chave: Abdominoplastia; Seroma; Lipectomia; Lipodistrofia; Contorno corporal

 

Effectiveness of Pessoa's universal technique for single marking in mastoplasty performed while training plastic surgeons

SALUSTIANO GOMES DE PINHO PESSOA; ALEKSANDRA MARKOVIC; JOSÉ ALBERTO DIAS LEITE
Rev. Bras. Cir. Plást. 2019;34(2):196-203 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: Reduction mastoplasty is still a challenging procedure for plastic surgeons. The Objective is to show the results of the treatment of different degrees of breast hypertrophy using Pessoa's single marking technique performed while training plastic surgeons.
Methods: A retrospective cohort of 95 patients underwent reduction mastoplasty using Pessoa's technique. The cohort included patients with breast ptosis, hypertrophy, gigantomastia, and/ or breast asymmetry. The procedures were performed by first-, second-, and third-year residents. The exclusion criteria were psychological disorders, morbid obesity, and/or indication for prosthesis implantation without skin and/or areola reduction. The analyzed factors were age, sex, final size, patient's degree of satisfaction, complications, and difficulties experienced by the residents in performing the surgery.
Results: All patients were women aged between 21 and 61 years. Of the patients, 90.53% reported being very satisfied; 5.26%, satisfied; 3.16%, poorly satisfied; and 1.05%, dissatisfied. The complications observed were necrosis of the nipple-areola complex (1.05%), epidermolysis (11.58%), and suture dehiscence (9.47%). The rate of difficulty experienced by the residents varied between 11.1% and 55.6%, depending on the step of the surgical procedure.
Conclusions: A high degree of satisfaction was reported by both the patients and residents. The results confirm the effectiveness of the technique while training residents.

Keywords: Mastoplasty; Plastic surgery; Breast; Body contour; Reconstructive surgical procedures

 

RESUMO

Introdução: A mamoplastia redutora é ainda um procedimento que desafia o cirurgião plástico. O objetivo é demonstrar os resultados no tratamento de variados graus de hipertrofia e ptose mamária utilizando-se a técnica de Marcação Única, proposta por Pessoa, durante o treinamento de novos cirurgiões plásticos.
Métodos: Coorte retrospectivo de 95 pacientes submetidas à mamoplastia redutora pela técnica de Pessoa. Incluídas pacientes com ptose, hipertrofia, gigantomastia e/ou assimetria das mamas. Os procedimentos foram realizados por residentes do primeiro, segundo e terceiro ano. Como fatores de exclusão foram usados: distúrbios psicológicos, obesidade mórbida e/ou pacientes com indicação de implante de prótese sem redução de pele e/ou aréola. Foram avaliados a idade, sexo, volume resultante, grau de satisfação, complicações e dificuldades dos residentes para realização do procedimento cirúrgico.
Resultados: Todas as pacientes do sexo feminino, com idade entre 21 e 61 anos. 90,53% das pacientes declararam-se muito satisfeitas, 5,26% satisfeitas, 3,16% pouco satisfeitas e 1,05% insatisfeita. Como complicações, foram observadas necrose de complexo areolopapilar (1,05%), epidermólise (11,58%) e deiscência de sutura (9,47%). As dificuldades encontradas pelos residentes, dependendo da etapa do procedimento cirúrgico, variaram entre 11,1% e 55,6%.
Conclusões: Verificou-se alto grau de satisfação tanto da parte das pacientes quanto dos residentes envolvidos. Os resultados encontrados confirmam a efetividade da técnica no treinamento de residentes.

Palavras-chave: Mamoplastia; Cirurgia plástica; Mama; Contorno corporal; Procedimentos cirúrgicos reconstrutivos

 

Comparative histopathological analysis of coverings from silicone and polyurethane foams implanted in mice

Jorge Wagenführ Júnior
Rev. Bras. Cir. Plást. 2007;22(1):19-23 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: Breast silicone prostheses are used since the sixties, but the coating with polyurethane foam only appeared in the seventies. Since the development of silicone foam, by this article's author, much research has been carried out to study this new material. Objective: To evaluate vascular growth and amount of collagen from coverings of polyurethane foam and silicone foam implants. Method: Sixty-four Wistar male white mice were divided in two groups (polyurethane foam and silicone foam). They were implanted with subcutaneous discs in their back. The covering of the implants were analyzed after 28 days, 2 months, 3 months and 6 months with picrosirius red stain and polarized microscopy. This stain increases birrefringency of collagen fibers when observed under polarized light. The slides were assessed in a double blind manner by an Olympus® B201 and BX50 microscope, Sony® CCD-Iris Camera and Image Pro-Plus® version 4.5 software for the analysis of the amount of collagen. Results: Vascular growth was significantly different among the groups at 28 days (p=0.001), since the polyurethane group displayed more vessels. At the other moments, there was no significant difference between the groups. The collagen area was larger in the polyurethane group, which was significant at 28 days (p=0.001) and at 2 months (p=0.030). Conclusion: The number of vessels is higher, 28 days after the procedure, in the polyurethane foam coverings. These also showed a larger amount of collagen than the coverings from silicone foams did.

Keywords: Prostheses and implants. Silicones. Polyurethanes

 

RESUMO

Introdução: O uso de próteses de silicone ocorre desde os anos 60, mas a cobertura com espuma de poliuretano só apareceu na década de 70. Desde o desenvolvimento da espuma de silicone, pelo autor deste trabalho, várias pesquisas vêm sendo feitas para estudar as propriedades desse novo material. Objetivo: Analisar a vascularização e a quantidade de colágeno das cápsulas de implantes de espuma de poliuretano e espuma de silicone. Método: Optou-se por 64 ratos Wistar, que foram divididos em 2 grupos (espuma de poliuretano e espuma de silicone). Receberam implantes discóides subcutâneos em seu dorso. Foram analisadas histologicamente, com coloração de picrosiruis red, as cápsulas peri-implante com 28 dias, 2, 3 e 6 meses após a introdução dos implantes. Esta coloração provoca aumento da birrefringência das fibras de colágeno ao serem observadas à luz polarizada. A leitura das lâminas, do tipo fechado, duplo cego, foi realizada com microscópio Olympus® B201 e BX50, Câmera Sony® CCD-Iris e Software Image Pro-Plus® versão 4.5 para quantificação de colágeno. Resultados: A neoformação vascular foi significativamente diferente nos 2 grupos, aos 28 dias (p=0,001), pois o grupo poliuretano apresentava quantidade maior de vasos. Nos demais momentos, não houve diferença significativa entre os grupos. A área de colágeno, em todos os momentos, foi maior no grupo poliuretano, sendo significativo com 28 dias (p=0,001) e com 2 meses (p=0,030). Conclusão: A quantidade de vasos é maior, com 28 dias após o implante, nas cápsulas da espuma de poliuretano. Estas apresentam, também, uma quantidade maior de colágeno do que as cápsulas da espuma de silicone.

Palavras-chave: Próteses e implantes. Silicones. Poliuretanos

 

Evaluation of the safety of VASERTM in liposuction surgery to improve body contour

Felipe Massignan
Rev. Bras. Cir. Plást. 2019;34(4):458-467 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: Liposuction has been improved continuously since it was first introduced. The third-generation ultrasound technology VASERTM (Vibration Amplification of Sound Energy at Resonance) facilitates liposuction, providing improved safety and satisfactory results, especially in the search for greater definition and superficial liposuction.
Methods: From 2015 to 2017, 76 patients underwent liposuction to improve their body contour at the Santa Monica Hospital Center in Erechim, Rio Grande do Sul, Brazil. The results, complications, and the safety of VASERTM were evaluated.
Results: The routine use of VASERTM improves body contour. The emulsification generated by the device, along with liposuction, resulted in greater definition and revelation of the anatomical landmarks.
Conclusion: Liposuction associated with VASERTM allows plastic surgeons to refine the results better while ensuring patient safety is maintained.

Keywords: Tissue; Lipodystrophy; Postoperative complications; Subcutaneous fat; Patient safety; Body contour.

 

RESUMO

Introdução: A lipoaspiração tem sido submetida à evolução constante desde a sua consolidação e emprego sistemático. O auxílio de tecnologia ultrassônica de terceira geração, VASER® (Vibration Amplification of Sound Energy at Resonance), se destina a facilitar a execução da lipoaspiração e trazer maior segurança e resultados satisfatórios, especialmente na busca por maior definição e lipoaspiração superficial.
Métodos: No período de 2015 a 2017, 76 pacientes foram submetidas à lipoaspiração para melhora de contorno corporal no Centro Hospitalar Santa Mônica em Erechim. Foram avaliados os resultados obtidos, as possíveis complicações e a segurança do emprego do VASER®.
Resultados: A utilização rotineira do VASER® gera aperfeiçoamento de resultados em contorno corporal. A emulsificação gerada pelo dispositivo associada à lipoaspiração em diversos níveis permite uma maior definição e evidenciação dos marcos anatômicos.
Conclusão: Lipoaspiração associada ao VASER® permite ao cirurgião plástico o refinamento de seus resultados com a preservação da segurança do paciente.

Palavras-chave: Tecido adiposo; Lipodistrofia; Complicações pós-operatórias; Gordura subcutânea; Segurança do paciente; Contorno corporal

 

Simple and composite circumferential abdominoplasty: technical evolution, 10-year experience and analysis of complications

WILSON CINTRA; MIGUEL MODOLIN; RODRIGO ITOCAZO ROCHA; ROLF GEMPERLI
Rev. Bras. Cir. Plást. 2021;36(1):21-27 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: Morbidly obese patients undergoing bariatric surgery after massive weight loss evolve with large skin folds in various body regions, including the abdomen. In patients with dermofat excesses throughout the abdominal circumference and ptosis of the gluteal region, circumferential abdominoplasty (simple or composite) has been an effective surgical solution conventional or "anchor" abdominoplasty brings unsatisfactory results in those patients with severe dysmorphia. The objective is to analyze the technical evolution of simple and composite circumferential abdominoplasty and its complications.
Methods: Twenty-nine patients were evaluated, 28 females, with a mean age of 41.17 years, submitted to circumferential abdominoplasty between 2002 and 2012. This retrospective study, conducted through data collected from medical records, evaluated: surgery time, the weight of the resected surgical specimen, length of hospital stays, antibiotic therapy used, associated complications, and changes in the surgical technique in this period.
Results: Composite circumferential abdominoplasty was performed in 23 patients (79.3%) and the simple one in six (20.7%). The mean surgical time was 346 minutes, and the surgical specimen's mean weight was 4323 grams. Three patients (10.3%) had significant complications (symptomatic anemia and major suture dehiscence) and five (17.2%) minor complications (minor dehiscence, slight spontaneous bleeding, seroma, and hypertrophic scarring). Between 2002 and 2004, 75% of the complications occurred. The reoperation rate was 6.9%.
Conclusion: There was a significant technical evolution in circumferential abdominoplasty performance, and the incidence of complications and the rate of reoperation were similar to those found in the literature.

Keywords: Abdominoplasty; Adverse effects; Skinfolds; Obesity; Morbid obesity; Body contour; Postoperative complications; Quality of life.

 

RESUMO

Introdução: Pacientes portadores de obesidade mórbida submetidos à cirurgia bariátrica, após perda ponderal maciça, evoluem com grandes dobras de pele em várias regiões do corpo, incluindo abdome. Nos pacientes com excessos dermogordurosos em toda circunferência abdominal e ptose da região glútea, a abdominoplastia circunferencial (simples ou composta) tem demonstrado ser uma solução cirúrgica eficaz, pois a abdominoplastia convencional ou "em âncora" traz resultados insatisfatórios naqueles pacientes com dismorfia severa. O objetivo é analisara evolução técnica da abdominoplastia circunferencial simples e composta e suas complicações.
Métodos: Foram avaliados 29 pacientes, sendo 28 do sexo feminino, com média etária de 41,17 anos, submetidos à abdominoplastia circunferencial, entre 2002 e 2012. Este estudo retrospectivo, realizado através de dados colhidos dos prontuários médicos, avaliou: tempo de cirurgia, peso da peça cirúrgica ressecada, tempo de internação hospitalar, antibioticoterapia utilizada, complicações associadas e alterações ocorridas na técnica operatória neste período.
Resultados: A abdominoplastia circunferencial composta foi realizada em 23 pacientes (79,3%) e a simples em seis (20,7%). O tempo cirúrgico médio foi de 346 minutos e o peso médio da peça operatória foi 4323 gramas. Três pacientes (10,3%) tiveram complicações maiores (anemia sintomática e deiscência de sutura maior) e cinco (17,2%) complicações menores (pequenas deiscências, pequeno sangramento espontâneo, seroma e cicatriz hipertrófica). Entre 2002 e 2004 ocorreram 75% das complicações. O índice de reoperação foi de 6,9%.
Conclusão: Houve importante evolução técnica na realização da abdominoplastia circunferencial, sendo que a incidência de complicações e a taxa de reoperação foram similares àquelas encontradas na literatura.

Palavras-chave: Abdominoplastia; Efeitos adversos; Pregas cutâneas; Obesidade; Obesidade mórbida; Contorno corporal; Complicações pós-operatórias; Qualidade de vida

 

Prevalence of body contouring surgery in post-bariatric patients at a university hospital

Luiz Henrique Zanata Pinheiro; Endrigo Torezan Rosim; Amanda Schroeder; Bruno Bracco Da-Silva; Davi Reis Calderoni; Elinton Adami Chaim; Paulo Kharmandayan
Rev. Bras. Cir. Plást. 2022;37(4):417-422 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: The growing number of patients with massive weight loss after bariatric surgery is correlated with the demand for body contouring surgery. Such procedures reduce physical and psychological complaints, positively influencing the quality of life of these people. However, there is little data on the response of services that offer surgical treatment for morbid obesity to this need. The study aims to measure the prevalence of body contouring surgery between 2015 and 2018, in patients previously underwent on a bariatric surgery, in 2014 and 2015, at a University Hospital.
Methods: Research in the hospital information system and medical records in order to assess the institutional prevalence of post-bariatric body contouring surgery. Patients who did not undergo both surgeries in our Service, those who underwent these surgical procedures in other years, as well as those with incomplete medical records were excluded.
Results: Bariatric surgeries were performed in 208 patients. Of these, 11% (n=23) underwent 27 body contouring surgeries, with abdominal dermolipectomy (n=16) being the most frequently performed. The performance of more than one procedure to correct body deformity occurred in 13% (n=3) of patients. The mean age of patients undergoing body contouring surgery was 37 years, the majority was female (96%, n=22).
Conclusion: Body contouring surgery is an important step in the treatment of morbid obesity and has a restorative feature. There is a huge lack of this therapy, which irreparably compromises the results obtained by bariatric surgery.

Keywords: Bariatric surgery; Reconstructive surgical procedures; Body contouring; Effective access to health services.

 

RESUMO

Introdução: O número crescente de pacientes com perda ponderal maciça, após cirurgias bariátricas, correlaciona-se com a procura por cirurgias de contorno corporal. Tais procedimentos reduzem queixas físicas e psicológicas, influenciando positivamente a qualidade de vida dessas pessoas. Todavia, há poucos dados quanto à resposta dos serviços que oferecem tratamento cirúrgico para obesidade mórbida frente a essa necessidade. O estudo tem como objetivo aferir a prevalência de cirurgia do contorno corporal entre 2015 e 2018, em pacientes previamente submetidos à cirurgia bariátrica, nos anos de 2014 e 2015, em um hospital universitário.
Métodos: Consulta ao sistema de informação hospitalar e a prontuários médicos a fim de aferir prevalência institucional de cirurgia de contorno corporal pós-bariátrica. Foram excluídos pacientes que não tenham sido submetidos a ambas as cirurgias em nosso Serviço, os que realizaram os referidos procedimentos cirúrgicos em outros anos, bem como aqueles com registros incompletos.
Resultados: Foram realizadas cirurgias bariátricas em 208 pacientes. Desses, 11% (n=23) foram submetidos a 27 cirurgias do contorno corporal, sendo a dermolipectomia abdominal (n=16) a mais realizada. A realização de mais de um procedimento para correção de deformidade corporal ocorreu em 13% (n=3) dos pacientes. A média de idade dos pacientes submetidos a cirurgia do contorno corporal foi de 37 anos, a maioria do sexo feminino (96%, n=22).
Conclusão: A cirurgia do contorno corporal constitui etapa importante do tratamento da obesidade mórbida e tem caráter reparador. Há imensa carência dessa terapêutica, o que compromete irremediavelmente os resultados obtidos pela cirurgia bariátrica.

Palavras-chave: Cirurgia bariátrica; Procedimentos cirúrgicos reconstrutivos; Contorno corporal; Acesso efetivo aos serviços de saúde.

 

Clinical and laboratory recovery of patients undergoing body liposuction associated with lipoabdominoplasty

Fabiel Spani Vendramin; Diego Rabelo Ferreira; Melissa Guevera Carrera
Rev. Bras. Cir. Plást. 2019;34(4):468-476 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: Body liposuction and abdominoplasty are surgeries often performed together to obtain superior results in body modeling. Since associated surgeries often increase spoliation, being aware of the evolution of hemoglobin (Hb) in the postoperative period and during the recovery of the patients undergoing these associated surgeries is important for their safety. This study aimed to analyze the decrease in Hb and the clinical and laboratory results throughout the recovery of patients undergoing body liposuction associated with lipoabdominoplasty.
Methods: A prospective study was conducted with patients undergoing body liposuction and lipoabdominoplasty. CBCs were collected before anesthetic induction, at the end of the surgery, before hospital discharge, after the 1st, 2nd, and 4th postoperative weeks, and during their clinical follow-up period.
Results: The average Hb values at the end of surgery and hospital discharge were 10.4 g/dL (standard deviation (SD) 0.76) and 8.92 g/dL (SD 0.86), respectively. The average values during the recovery of Hb after the 1st, 2nd, and 4th weeks were 2.4% (SD 18.07), 41.6% (SD 18.4), and 74% (SD 15.2), respectively. This is in relation to the reduction between the initial Hb and at hospital discharge. Complaints of weakness and lipothymia were frequent until the second day.
Conclusion: Clinical improvement was observed until the second postoperative day (PO day). Hemoglobin required approximately 1 month to normalize in most patients. These patients were treated only with oral iron replacement and did not require blood transfusions.

Keywords: Body contouring; Abdominoplasty; Lipectomy; Clinical evolution; Laboratory investigation; Anemia.

 

RESUMO

Introdução: A lipoaspiração corporal e abdominoplastia são cirurgias muitas vezes realizadas em conjunto para obter melhores resultados na modelagem corporal. Cirurgias associadas sempre aumentam a espoliação, por isto conhecer o comportamento da hemoglobina (Hb) no pós-operatório e a recuperação do paciente submetido a estas cirurgias combinadas é importante para sua segurança. O objetivo deste trabalho foi estudar a queda da Hb e a recuperação clínica e laboratorial dos pacientes submetidos à cirurgia combinada de lipoaspiração corporal e lipoabdominoplastia.
Métodos: Realizou-se um estudo prospectivo em pacientes submetidos à lipoaspiração corporal e lipoabdominoplastia, coletando-se hemogramas antes da indução anestésica, ao final da cirurgia, antes da alta hospitalar, após a 1ª, 2ª e 4ª semanas de pós-operatórios e também acompanhando suas evoluções clínicas.
Resultados: A média da Hb ao final da cirurgia e na alta hospitalar foi de 10,4g/dl (desvio padrão (DP) 0,76) e 8,92g/dl (DP 0,86), respectivamente. A recuperação em média da Hb após 1ª, 2ª e 4ª semanas foi de 2,4% (DP 18,07), 41,6% (DP 18,4) e 74% (DP 15,2), respectivamente, em relação a redução que ocorreu entre a Hb inicial e a da alta hospitalar. Queixas de fraqueza e lipotimia foram frequentes até o segundo dia.
Conclusão: A melhora clínica ocorreu até o segundo dia de pós-operatório (DPO) e a hemoglobina levou aproximadamente 1 mês para normalizar na maioria dos pacientes tratados apenas com reposição oral de ferro, sem necessidade de hemotransfusão.

Palavras-chave: Contorno corporal; Abdominoplastia; Lipectomia; Evolução clínica; Investigação laboratorial; Anemia

 

Abdominal etching

Maurício Schneider Salomone Viaro
Rev. Bras. Cir. Plást. 2019;34(3):336-343 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: Abdominal etching involves improvement of the appearance of the abdominal musculature by removing fat from several skin layers, including the superficial layer. This study evaluated the aesthetic results of abdominal etching using liposuction.
Methods: The aesthetic results and surgical complications of female patients were evaluated between 2017 and 2018. All study patients answered a standard questionnaire about the extent of improvement in body image, overall satisfaction level, naturalness of the result, and changes in exercise and dietary habits.
Results: The mean patient age was 38.97 years, while the mean body mass index was 24.01. In our sample, 75% of the subjects had previous pregnancies, 25% had previous abdominal surgeries, and 2.5% had a history of smoking. Simultaneous surgeries were performed in 90% of cases. The following surgery types were performed: liposuction alone (40.00%), liposuction + abdominoplasty (36.25%), miniabdominoplasty (12.50%), abdominoplasty + liposuction (10.00%), and reverse abdominoplasty (1.25%). Moderate aesthetic improvement was observed in 86.25% of the patients, and surgical complications occurred in eight patients. The satisfaction rate was 91.7%, and the result was classified as natural by 97.5% of the patients.
Conclusion: Abdominal etching promoted high patient satisfaction and achieved a natural appearance of the abdomen. This surgical outcome was achieved using conventional liposuction without the need for additional techniques. However, further studies are needed to evaluate long-term outcomes.

Keywords: Lipectomy; Abdominoplasty; Abdominal fat; Body contouring; Aesthetics

 

RESUMO

Introdução: A lipoaspiração de definição abdominal consiste na criação de sulcos em locais específicos do abdome através da retirada de gordura em toda sua espessura, incluindo a camada superficial, permitindo um maior detalhamento da musculatura. O objetivo deste estudo foi avaliar os resultados da técnica de lipoaspiração na definição abdominal.
Métodos: Foram avaliadas 80 pacientes do sexo feminino no período de 2017 a 2018. O grau de definição e as complicações relacionadas ao procedimento foram avaliadas pelo autor. Todas as pacientes responderam um questionário padrão sobre grau de definição abdominal, satisfação, naturalidade do resultado, aumento da atividade física e melhora da alimentação.
Resultados: A média de idade das pacientes foi de 38,97 anos e a média de índice de massa corporal, 24,01. Gestação prévia foi observada em 75% dos casos, cirurgia abdominal pregressa em 25% e tabagismo em 2,5%. Cirurgias simultâneas foram realizadas em 90%. Em relação ao tipo de cirurgia realizada, ocorreu a seguinte distribuição: 40% lipoaspiração isolada, 36,25% lipoabdominoplastia, 12,5% minilipoabdominoplastia, 10% lipoaspiração pós-abdominoplastia e 1,25% lipoabdominoplastia reversa. Grau 2 de definição abdominal foi observado em 86,25% e complicações ocorreram em 8 pacientes. O índice de satisfação foi de 91,7% e o resultado foi classificado como natural por 97,5% das pacientes.
Conclusão: A lipoaspiração de definição abdominal promoveu um alto índice de satisfação e naturalidade à região abdominal. Esse resultado pode ser atingido através da técnica de lipoaspiração convencional, sem nenhum dispositivo tecnológico adicional. Contudo, são necessários novos estudos para avaliação dos resultados em longo prazo.

Palavras-chave: Lipectomia; Abdominoplastia; Gordura abdominal; Contorno corporal; Estética

 

The main abdominoplasty techniques used in post-bariatric patients after massive weight loss: systematic review

Eurico Arteaga Santiago; Thais Conte Dias Bencini Andrighetti; Matheus Lucena Miranda Meroni; Thays Favaro Fernandes Nolasco; Rodrigo Contente; Carolina Lacerda Souza
Rev. Bras. Cir. Plást. 2023;38(1):1-7 - Review Article

PDF Portuguese PDF English

ABSTRACT

Introduction: Obesity is defined by a body mass index (BMI) =30 kg/m2, and today approximately 2.1 billion adults are obese. With this high number of obese people, the demand for treatment via bariatric surgery has been increasing to reduce weight, resolve comorbidities and improve quality of life. However, intense weight loss can cause adverse physical, aesthetic, and psychological effects. Plastic surgery becomes essential to resolve these adverse effects. According to the International Society of Plastic Surgery, 112,116 abdominoplasties were performed in 2020, representing 8.6% of all plastic surgeries performed in Brazil. The objective is to present the main abdominoplasty techniques in postbariatric patients.
Method: Studies that met the previously defined inclusion criteria were included.
Results: A total of 28 references were included in this systematic review.
Discussion: Most seek abdominoplasty due to the excess skin remaining in various body regions and the impact on post-bariatric patients' quality of life and mental health. The surgical techniques addressed are classic abdominoplasty; fleur-de-lis or anchor; circumferences; and Scarpa's fascia. The total number of complications was 42%; the main ones observed were scarring, skin dehiscence, infection, and necrosis; the three added up to 32%.
Conclusion: The improvement in the quality of life of patients undergoing abdominoplasty is evident, but further research is needed to relate abdominoplasty techniques to these patients with postoperative complications.

Keywords: Abdominoplasty; Patients; Bariatric surgery; Reconstructive surgical procedures; Body contouring

 

RESUMO

Introdução: A obesidade é definida pelo índice de massa corporal (IMC) =30 kg/m2, e hoje cerca de 2,1 bilhões de adultos são obesos. Com esse alto número de obesos, a procura por tratamento via cirurgia bariátrica vem aumentando com o intuito de redução de peso, resolução de comorbidades e melhora da qualidade de vida. Entretanto, a intensa perda de peso pode ocasionar efeitos adversos físicos, estéticos e psicológicos. A cirurgia plástica passa a ser fundamental para resolução desses efeitos adversos. Segundo a Sociedade Internacional de Cirurgia Plástica, foram realizados 112.116 abdominoplastias em 2020, representando 8,6% de todas as cirurgias plásticas realizadas no Brasil. O objetivo é apresentar as principais técnicas de abdominoplastia em pacientes pós-bariátricos.
Método: Foram incluídos estudos que cumprissem os critérios de inclusão previamente definidos.
Resultados: Foi incluído nesta revisão sistemática um total de 28 referências.
Discussão: Devido ao excesso de pele remanescente em várias regiões do corpo e o impacto na qualidade de vida e saúde mental dos pacientes pós-bariátricos, a maioria procura por abdominoplastia. As técnicas cirúrgicas abordadas são abdominoplastia clássica; flor-de-lis ou âncora; circunferências; e fáscia de Scarpa. O total de complicações foi de 42%, as principais observadas foram de cicatrização; deiscência de pele, infecção e necrose; as três somaram 32%.
Conclusão: A melhora na qualidade de vida dos pacientes submetidos a abdominoplastia é evidente, porém é necessária a realização de mais pesquisas que relacionem as técnicas de abdominoplastia nesses pacientes com suas complicações pós-operatórias.

Palavras-chave: Abdominoplastia; Pacientes; Cirurgia bariátrica; Procedimentos cirúrgicos reconstrutivos; Contorno corporal

 

Evaluation of the degree of aesthetic satisfaction after subcutaneous gluteal fat grafting

Alysson Rogério Matioski; Eduardo Pianaro Caron; Gabriel Paiva Kroneis
Rev. Bras. Cir. Plást. 2023;38(2):1-6 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: Body exposure, especially in the gluteal region, has increased the demand for gluteoplasty surgery. Autologous adipose tissue has been used to correct soft tissue defects since the beginning of the last century. Its smooth, natural texture, availability in sufficient quantities, and potentially permanent integration make adipose tissue the ideal physiological filler material. In this context, gluteal fat grafting, when compared with the use of gluteal implants, offers a faster recovery period and fewer complications in the medium and long term.
Method: A prospective study was conducted using the gluteal evaluation questionnaire in patients who underwent subcutaneous gluteal fat grafting from August to December 2019. The collected data were submitted for statistical analysis by Student's t-test.
Results: Forty patients (39 females and 1 male) who underwent subcutaneous gluteal fat grafting were selected. The average age presented in the study was 36.55 years. The mean body mass index was 27.38 kg/m2. The most frequent comorbidities were varicose veins, anemia, and hypertension. In most of the hypotheses evaluated, there was a significant improvement in the quality of life of the selected patients.
Conclusion: Subcutaneous gluteal fat grafting improves patients' quality of life, which is demonstrated by the high level of satisfaction after performing this procedure.

Keywords: Reconstructive surgical procedures; Lipectomy; Allografts; Buttocks; Patient satisfaction

 

RESUMO

Introdução: A exposição corporal, especialmente da região glútea, tem proporcionado atualmente um aumento da procura pela cirurgia de gluteoplastia. O tecido adiposo autólogo é usado para corrigir defeitos dos tecidos moles desde o início do século passado. Sua textura suave e natural, disponível em quantidades suficientes, e sua integração potencialmente permanente são características que fazem do tecido adiposo ser o material de preenchimento fisiológico ideal. Nesse contexto, a lipoenxertia glútea, quando comparada com o uso de implantes glúteos, oferece um período de recuperação mais rápido e menos complicações a médio e longo prazo.
Método: Foi realizado um estudo prospectivo com a aplicação do questionário de avaliação dos glúteos nas pacientes submetidas a lipoenxertia glútea subcutânea no período de agosto a dezembro de 2019. Os dados coletados foram submetidos a análise estatística pelo teste t de Student.
Resultados: Foram selecionados 40 pacientes (39 do sexo feminino e 1 do sexo masculino) que foram submetidos a lipoenxertia glútea subcutânea. A média da idade apresentada no estudo foi de 36,55 anos. A média do índice de massa corporal foi de 27,38 Kg/m². As comorbidades mais frequentes foram varizes, anemia e hipertensão. Na maior parte das hipóteses avaliadas houve melhora significativa na qualidade de vida dos pacientes selecionados.
Conclusões: A lipoenxertia glútea subcutânea melhora a qualidade de vida dos pacientes, o que é demonstrado pelo alto nível de satisfação após a realização desse procedimento.

Palavras-chave: Procedimentos cirúrgicos reconstrutivos; Lipectomia; Aloenxertos; Nádegas; Satisfação do paciente

 

Esthetic refinements to the appearance of the vulva in sex reassignment surgery

MATHEUS ZAMIGNAN MANICA
Rev. Bras. Cir. Plást. 2019;34(1):65-73 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: Sex reassignment surgery is a reliable and safe option, which has drastically reduced dysphoria and improved the quality of life of transgender individuals. The most studied and used technique is penile inversion with modifications, which results in appropriate esthetic appearance and functionality, but the surgical technique has not been standardized. Partial satisfaction rates up to 38% and dissatisfaction rates of 15% may cause up to 66% of cases to undergo additional procedures. The objective is to suggest esthetic refinements to the appearance of the vulva and compare some of the techniques described, seeking to increase the postoperative esthetic and functional satisfaction.
Methods: A retrospective study with 7 patients undergoing sex reassignment surgery between August 2017 and February 2018 was conducted. The clitoris is constructed with the glans in the form of a trident, using the corona to build the corpus cavernosa of the clitoris and increase the area of erogenous sensation. A section of the prepuce is used to increase the coverage of the clitoris and cover the inner surface of the labia minora, which are defined with the use of sutures.
Results: Adequate sensitivity and satisfaction with the result and capacity of orgasm in all patients were observed. There was no stenosis, fistula, or necrosis of the clitoris with this technique. Only 1 case needed an additional procedure for better esthetic definition.
Conclusion: The technique presented leads to high patient satisfaction and erogenous sensitivity, with some advantages compared to other techniques. However, prospective studies with larger numbers of patients are needed to define a more effective surgical technique.

Keywords: Vulva; Transsexualism; Transgender Individuals; Sex Reassignment Surgery; Sex Reassignment Procedures

 

RESUMO

Introdução: A cirurgia de adequação genital tem se mostrado uma opção segura e confiável, com redução drástica na disforia e melhora da qualidade de vida das pessoas transgênero. A técnica mais estudada e utilizada é a inversão peniana com suas modificações, com aparência estética e funcionalidade adequadas, porém sem padronização da técnica cirúrgica. Índices de até 38% de satisfação parcial e 15% de insatisfação podem levar até 66% dos casos a realizar procedimentos adicionais. O objetivo é sugerir refinamentos estéticos na aparência da vulva e comparar com algumas das técnicas descritas, buscando aumentar a satisfação estética e funcional pós-operatória.
Métodos: Estudo retrospectivo com 7 pacientes submetidas à cirurgia de readequação sexual entre agosto de 2017 e fevereiro de 2018. O clitóris é feito com a glande em formato de tridente, utilizando a coroa para construir os corpos cavernosos do clitóris e aumentar a área de sensação erógena. Faixa de prepúcio é usada para aumentar a cobertura do clitóris e cobrir a face interna dos pequenos lábios, que são definidos com o uso de suturas.
Resultados: Sensibilidade adequada e satisfação com o resultado e capacidade de orgasmo em todas as pacientes observadas. Não houve estenose, fístula ou necrose do clitóris com essa técnica. Somente 1 caso precisou de procedimento adicional para melhor definição estética.
Conclusão: A técnica apresentada tem alta satisfação das pacientes e sensibilidade erógena, com algumas vantagens em relação a outras técnicas. Porém, estudos prospectivos com número maior de pacientes são necessários para definir a técnica cirúrgica mais efetiva.

Palavras-chave: Vulva; Transexualismo; Pessoas Transgênero; Cirurgia de Readequação Sexual; Procedimentos de Readequação Sexual

 

Other trends in abdominoplasty: new design and importance of lipo-mid-abdominoplasty in body contour surgery

Alberto Magno Lott Caldeira; Carolina Duran; Juan Camilo Holguín
Rev. Bras. Cir. Plást. 2020;35(1):60-71 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: During the last few years, the surgical principles of abdominoplasty have remained unchanged. Therefore, many patients undergoing this technique have misalignment and high and straight transverse scars of the abdomen, with the final position of the umbilical scar being very close to the transverse scar, making the abdomen seem short. We propose modifying the basic concept of marking in abdominoplasty, because we believe it is important to position the transverse scar lower in the medial and pubic region and higher at the lateral ends, allowing anterior lumbar flap rotation in an inferomedial direction.
Methods: We retrospectively analyzed 146 patients with abdominal defects and subjected them to lipomid-abdominoplasty, marking with strong upper concavity and guiding the sides of the scar towards the lower transverse line of the abdomen, 4 cm equidistant from the root of the thigh. We also define liposuction as a complementary treatment to body contouring.
Results: We consider that mid-abdominoplasty parameters are applicable in most cases, obtaining satisfactory results both in patients with flatness and supraumbilical abdominal lipodystrophy and patients with an "apron" abdomen with considerable flaccidity and diastasis of the abdominal rectus.
Conclusion: It is important to determine the area of the abdominal defect and its classification to establish treatment strategies and association with complementary procedures. A lower marking with respect to the treatment areas will allow a more aesthetic scar and a harmonic body contour as well as an adequate placement of the umbilical scar, pubis, and lateral ends of the transverse abdominal scar.

Keywords: Abdominoplasty; Body contour; Lipectomy; Abdominal fat; Body surface; Abdominal rectus; Abdominal wall; Umbilicus; Fat tissue.

 

RESUMO

Introdução: Durante os últimos anos, os princípios cirúrgicos da abdominoplastia permaneceram inalterados. Portanto, muitos resultados observados apresentam desalinhamento, cicatrizes transversais altas e retas do abdome, levando ao posicionamento final da cicatriz umbilical a ser muito próximo da cicatriz transversal, o que dá a impressão de abdome curto. Propomos que a abdominoplastia modifique a concepção básica de sua marcação, pois acreditamos que é importante posicionar a cicatriz transversal mais baixa na região medial e púbica, e mais alta nas extremidades laterais, permitindo, no nível dos flancos, a rotação dos retalhos lombares no sentido anterior em direção inferomedial.
Métodos: Foram analisados de forma retrospectiva 146 pacientes portadores de deformidades abdominais e os submetemos a lipomidiabdominoplastia, marcando com forte concavidade superior e orientando os lados da cicatriz em direção à linha transversa inferior do abdômen, 4cm equidistantes da raiz da coxa. Também associamos a lipoaspiração como um tratamento complementar ao contorno corporal.
Resultados: Consideramos que os parâmetros da midiabdominoplastia são aplicáveis na maioria dos casos, obtendo resultados igualmente satisfatórios, tanto nos pacientes com flacidez e lipodistrofia abdominal supraumbilical, quanto nos pacientes com abdome em avental com importante flacidez e diástase dos retos abdominais.
Conclusão: É importante determinar a área da deformidade abdominal e sua classificação, para estabelecer as estratégias do tratamento e associação de procedimentos complementares. Uma marcação mais baixa, respeitando as áreas de tratamento, permitirá uma melhor cicatriz estética e um contorno corporal harmônico, além de uma adequada colocação dos elementos: cicatriz umbilical, púbis e extremidades laterais da cicatriz abdominal transversa.

Palavras-chave: Abdominoplastia; Contorno corporal; Lipectomia; Gordura abdominal; Superfície corporal; Reto do abdome; Parede abdominal; Umbigo; Tecido adiposo

 

Mammoplasty after massive weight loss

Marina Junqueira Ferreira Rosique; Rodrigo Gouvêa Rosique
Rev. Bras. Cir. Plást. 2014;29(3):375-383 - Original Article

PDF Portuguese PDF English

ABSTRACT

INTRODUCTION: After massive weight loss, patients present with various mammary changes, such as sagging, different grades of ptosis, and empty upper pole. Different mammoplasty techniques are used to shape the mammary cone and to reposition the nipple-areolar complex (NAC). In this study, we evaluate how different surgical approaches can satisfy the requirements of each patient. METHOD: Twenty-five patients who underwent mammoplasty following gastroplasty were analyzed. The mammoplasty techniques used were (1) mastopexy without implant with inferior flap; (2) mastopexy without implant with inferior areolar pedicle; (3) mastopexy with implant and coverage by inferior flap; (4) mastopexy with implant and plication of cross flaps (jacket procedure). RESULTS: The average body mass index (BMI) before mammoplasty was 26.6 (ranging from 21.6 to 31.2). All patients who underwent this surgery rated the outcome obtained as good or great. In an evaluation carried out by an observer unaware of the techniques employed, the results obtained were considered to be satisfactory for breast shape, correction of breast ptosis, and filling of the upper pole. One patient who underwent mastopexy with implants and cross flaps developed seroma and subsequent capsular contracture, which required capsulectomy. Eight patients developed unilateral dehiscence: seven at the junction of skin flap in the inframammary fold, and one vertically, which were resolved with healing by secondary intention. No cases of necrosis or NAC epitheliosis were observed. CONCLUSION: Using different mammoplasty techniques, which were personalized and analyzed on a case-by-case basis, good outcomes and a high level of patient satisfaction were achieved. Various factors, such as the furcula-papilla distance, the need to lift the NAC, pre-mammoplasty breast volume and the patient's desire to increase breast volume, influence the choice of the surgical technique.

Keywords: Body contour; Massive weight loss; Mastopexy; Mamomplasty.

 

RESUMO

INTRODUÇÃO: Após perda ponderal maciça, as pacientes apresentam alterações mamárias, como flacidez, ptose em graus variados e polo superior vazio. Diferentes técnicas de mamoplastia são empregadas para dar forma ao cone mamário e reposicionar o complexo aréolo-papilar (CAP). Neste trabalho, avaliamos diferentes abordagens cirúrgicas preenchendo as necessidades de cada caso. MÉTODO: Vinte e cinco pacientes submetidas à gastroplastia antes da mamoplastia foram analisadas. As técnicas utilizadas foram (1) mastopexia sem prótese e retalho inferior; (2) mastopexia sem prótese e pedículo areolado inferior; (3) mastopexia com prótese com cobertura pelo retalho inferior; (4) mastopexia com prótese com plicatura de retalhos cruzados (jaquetão). RESULTADOS: A média do IMC antes da mamoplastia foi de 26,6 (variando de 21,6 a 31,2). Todas as pacientes submetidas à cirurgia consideraram o resultado bom ou ótimo. Em avaliação por observador cego às técnicas empregadas, os resultados foram considerados bons com relação à forma da mama, correção da ptose e preenchimento do polo superior. Uma paciente submetida à mastopexia com prótese com retalhos cruzados apresentou seroma e contratura capsular subsequente, necessitando capsulectomia. Oito pacientes apresentaram deiscências: sete, na junção dos retalhos cutâneos no sulco inframamário, e uma na vertical, unilateralmente, resolvidas por cicatrização por segunda intenção. Não houve caso de necrose ou epiteliólise do CAP. CONCLUSÃO: Empregando-se diferentes técnicas de mamoplastia, individualizadas caso a caso, foram obtidos resultados agradáveis, alcançando satisfação das pacientes. Fatores, como distância fúrcula-papila, necessidade de elevação do CAP, volume mamário pré-mamoplastia e desejo de aumento de volume pela paciente, influenciam a escolha da técnica cirúrgica.

Palavras-chave: Contorno corporal; Perda ponderal maciça; Mastopexia; Mamoplastia.

 

Breast augmentation: "envelope flap" technique

Carlos Eduardo Guimarães Leão
Rev. Bras. Cir. Plást. 2009;24(2):202-207 - Original Article

PDF Portuguese PDF English

ABSTRACT

The retromuscular positioning of the mammary implants for the "Envelope Flap" technique demystifies definitely the possibility of the evolution for a "double breast" in the late augmentation mammaplasty follow-up, caused by the prosthesis imprisonment for mechanical action of the great pectoral muscle when it is not treated appropriately. The author proposes the treatment of the above-mentioned muscle through two oblique incisions of inferior convergence done in his inferior edge that allows a total freedom of the implant movement that accompanies the breast bascule movement along the time, maintaining a natural appearance in all the periods of this evolution.

Keywords: Silicones. Breast implants. Mammaplasty.

 

RESUMO

O posicionamento retromuscular dos implantes mamários pela técnica em "Aba de Envelope" desmistifica definitivamente a possibilidade da evolução para uma "dupla mama" no seguimento tardio das mamaplastias de aumento, causada pelo encarceramento das próteses por ação mecânica do grande peitoral, quando não tratado adequadamente. O autor propõe o tratamento do referido músculo através de duas incisões oblíquas de convergência inferior, feitas em sua borda inferior, o que permite total liberdade de movimentação do implante que acompanha os movimentos de báscula das mamas ao longo do tempo, mantendo um resultado de total naturalidade em todos os períodos desta evolução.

Palavras-chave: Silicones. Implantes de mama. Mamoplastia.

 

Uso da terapia de pressão negativa no tratamento de deiscência em abdominoplastia de paciente pós-bariátrico: relato de caso

LÍVIA NEFFA; VALÉRIA ROCHA MAIA; CLÊNIO MARTINS DE SOUZA COELHO; IZABELLA COSTA ARAÚJO
Rev. Bras. Cir. Plást. 2019;34(Suppl.2):41-44 - Supplement Symposium Miner of Intercurrences 13th SYMPOSIUM - 2019

PDF Portuguese

RESUMO

Introdução: As deiscências são complicações frequentes nas abordagens de contorno abdominal, e os pacientes pós-cirurgias bariátricas possuem riscos maiores de complicações. Na literatura, a grande maioria das deiscências tem conduta conservadora, aguardando uma cicatrização por segunda intenção; porém, a terapia de pressão negativa, já consagrada para tratamento de feridas complexas, pode ser uma boa alternativa para as deiscências abdominais.
Objetivo: Demonstrar o uso de terapia de pressão negativa com fechamento primário retardado como uma alternativa à cicatrização por segunda intenção na abordagem de deiscências pós-dermolipectomia abdominal.
Relato de caso: Paciente, gênero feminino, diabética, tabagista e hipertensa, 53 anos, submetida à cirurgia bariátrica com perda ponderal estável de 30 kg dois anos antes da avaliação para tratamento do contorno corporal. Submetida à dermolipectomia abdominal em âncora com a neo-onfaloplastia sem intercorrências imediatas. Com sete dias, apresentou quadro compatível com seroma de drenagem espontânea com deiscência e posterior infecção de ferida. Após insucesso do tratamento ambulatorial, foi internada e tratada com antibioticoterapia venosa e uso de terapia de pressão negativa em zona de deiscência. Apresentou melhora clínica e laboratorial com o tratamento possibilitando, inclusive, fechamento completo da deiscência apresentada pela paciente.
Discussão: Seroma, infecção e deiscência são complicações frequentes em procedimentos cirúrgicos. O uso da terapia de pressão negativa já é descrita pela literatura como opção em feridas complexas, e se encaixou com uma boa opção do caso relatado.
Conclusão: O caso relatado demonstra que a terapia de pressão negativa pode ser uma alternativa para o tratamento de deiscências pós-dermolipectomias abdominais.

Palavras-chave: Procedimentos cirúrgicos reconstrutivos; Cirurgia bariátrica; Gastroplastia; Abdominoplastia; Obesidade; Vácuo; Deiscência da ferida operatória; Tratamento de ferimentos com pressão negativa; Contorno corporal

 

Severe complication by irregular use of industrial silicone in a transsexual patient: a case report

Monique Mendes; Gustavo Gomes Ribeiro Monteiro; Emilly Freire Barbosa Bastos; Dimas André Milcheski; Araldo Ayres Monteiro; Rolf Gemperli
Rev. Bras. Cir. Plást. 2020;35(3):358-362 - Case Reports

PDF Portuguese PDF English

ABSTRACT

The use of industrial liquid silicone as a material for aesthetic modification of body contour is a practice that has been carried out clandestine for about 60 years. Currently, most reports come from countries in Asia and South America, and the victims are mainly women and transsexuals. Due to the large number of cases with complications, the use of industrial silicone for aesthetic purposes has never been approved. However, it continues to be applied alone or associated with other products, determining severe local and systemic complications. We report a case of death of a transsexual patient after injecting industrial silicone in the thighs and buttocks.

Keywords: Silicones; Death; Allografts; Necrosis; Transgender people; Body contour.

 

RESUMO

O uso do silicone líquido industrial como material para modificação estética no contorno corporal é uma prática realizada de forma clandestina há cerca de 60 anos. Atualmente, a maioria dos relatos provém de países da Ásia e América do Sul e as vítimas são principalmente mulheres e transexuais. Devido ao grande número de casos com complicações, o uso do silicone industrial para fins estéticos nunca foi aprovado. Entretanto, continua a ser aplicado isoladamente ou associado a outros produtos, determinando graves complicações locais e sistêmicas. Relata-se um caso de óbito de paciente transexual após injeção de silicone industrial em coxas e glúteos.

Palavras-chave: Silicones; Morte; Aloenxertos; Necrose; Pessoas transgênero; Contorno corporal

 

Bone reabsorption associated with silicone implants in mentoplasty: a clinical case report

Gabriel Cardoso Ramalho; Sérgio Luís de Miranda; Roberto Moreno; Henrique Celestino Lima e Silva; Maria Victoria de Freitas Miranda
Rev. Bras. Cir. Plást. 2017;32(2):291-294 - Case Report

PDF Portuguese PDF English

ABSTRACT

For many years, silicone implants were used in reconstructive and esthetic surgeries, especially in cases in which the facial profile of patients presented deficiencies in the inferior third of the face. This material proved to be successful in most aspects. However, several complications were well reported in the literature, as the case of bone reabsorption in the region of the mandibular chin. In this article, the authors present two clinical cases of bone reabsorption from the anterior cortex of the chin associated with silicone implants and discuss the etiology, complications, and treatment plan.

Keywords: Mentoplasty; Bone reabsorption; Silicones.

 

RESUMO

Durante muitos anos, os implantes de silicone foram utilizados em cirurgias reconstrutivas e estéticas, principalmente em casos em que o perfil facial do paciente apresenta deficiência no terço inferior da face. Este material tem provado ser bem sucedido na maioria dos aspectos, contudo, algumas complicações já foram bem relatadas na literatura, como é o caso das reabsorções ósseas na região de mento mandibular. No presente artigo os autores apresentam dois casos clínicos de reabsorção óssea da cortical anterior do mento, associada ao implante de silicone e discutem a etiologia, as complicações e o plano de tratamento.

Palavras-chave: Mentoplastia; Reabsorção óssea; Silicones.

 

Complicações em cirurgias plásticas após perdas ponderais maciças: uma busca sistemática e revisão

JOANNA GUELLER BECKER; ELVIO BUENO GARCIA; JUAN CARLOS MONTANO PEDROSO; LYDIA MASAKO FERREIRA
Rev. Bras. Cir. Plást. 2019;34(Suppl.2):75-78 - Supplement Symposium Miner of Intercurrences 12th SYMPOSIUM - 2018

PDF Portuguese

RESUMO

Introdução: A obesidade é uma doença prevalente e pandêmica. Após perdas ponderais maciças obtidas através da cirurgia bariátrica, a cirurgia plástica tem apresentado crescimento evidente. Entretanto, pacientes pós-bariátricos apresentam maior incidência de complicações. O objetivo deste estudo foi realizar uma busca sistemática e revisão das complicações das cirurgias de contorno corporal após grandes perdas ponderais.
Métodos: Realizada busca sistemática e revisão, na língua inglesa, utilizando as bases Medline/PubMed, Cochrane Library e SciELO. A busca foi feita cruzando o descritor complicações com os seguintes termos: plástica pós-bariátrica; plástica após perda ponderal maciça; contorno corporal.
Resultados: A população analisada resultou em 1.167 pacientes, submetidos a 1.791 procedimentos cirúrgicos, através da seleção de sete artigos na literatura, sendo dois prospectivos e cinco retrospectivos. Obteve-se a taxa de complicação geral (26,9% a 55,5%) e a taxa de reoperações (0% a 13,4%). A complicação mais frequente encontrada foi dificuldade de cicatrização, seguida de seroma, infecção, epidermólise, hematoma, deiscência maior, anemia, embolismo e óbito.
Conclusão: Pacientes com perda ponderal maciça apresentam tendência elevada a complicações pós-operatórias, sendo a principal a dificuldade de cicatrização - deiscência menor. Há necessidade de maior conhecimento dos fatores específicos envolvidos a fim de reduzir a incidência de complicações.

Palavras-chave: Complicações em cirurgia plástica; Cirurgia plástica; Plástica pós-bariátrica; Plástica após perda ponderal maciça; Contorno corporal; Complicações

 

Indexers

Licença Creative Commons All scientific articles published at www.rbcp.org.br are licensed under a Creative Commons license