ISSN Online: 2177-1235 | ISSN Print: 1983-5175
Showing of 1 until 7 from 7 result(s)
Search for : RAIDEL DEUCHER RIBEIRO
ABSTRACT
Introduction: Prophylactic contralateral mastectomy (PCM)
has been increasingly indicated in recent years for patients
outside of the high-risk group, although its cancer benefit
in terms of survival remains controversial. The possibility
of breast reconstruction is one of the most important factors
for this indication. The objective of this study was to evaluate
the indications and complications after immediate breast
reconstruction in patients who underwent PCM.
Method:
Indications and complications were evaluated in patients who
underwent immediate breast reconstruction after therapeutic
mastectomy and PCM.
Results: Of the 13 patients in the study,
only 4 had a high-risk indication for PCM (strong family history).
The other indications were desire for symmetry, control of
anxiety related to neoplasm recurrence, and age-related
risk. Only minor complications occurred, without a need for
reoperation, in 4 of the 13 patients (30.76%). Eight complications
(30.76%) in 26 reconstructed breasts were recorded.
Conclusion:
The number of PCM procedures has been increasing and the
indications transcend the oncological point of view, directly
influencing the performance of plastic surgeons with respect
to the planning and complications of breast reconstruction.
Keywords: Subcutaneous mastectomy; Breast implant; Breast neoplasms; Postoperative complications; Risk factors; Mammoplasty
RESUMO
Introdução: A indicação da mastectomia contralateral profilática (MCP) tem aumentado nos
últimos anos nas pacientes fora do grupo de alto risco, apesar de seu
benefício oncológico controverso em relação à sobrevida. A possibilidade da
reconstrução mamária é um dos fatores mais importantes desse aumento. O
objetivo é avaliar pacientes submetidas à MCP quanto às indicações e
complicações após a reconstrução imediata.
Método: Avaliação das pacientes submetidas à reconstrução mamária imediata após
mastectomia terapêutica e MCP quanto às indicações e complicações.
Resultados: Das 13 pacientes do estudo, apenas 4 apresentavam indicação de MCP por alto
risco (forte história familiar). As outras indicações foram busca pela
simetria, controle da ansiedade em relação à nova neoplasia e risco
acumulado pela idade. Ocorreram apenas complicações menores, sem necessidade
de reoperação em 4 das 13 pacientes (30,76%) e num total de 26 mamas
reconstruídas foram registradas 8 complicações (30,76%).
Conclusão: A realização da MCP tem aumentado, sendo que as indicações transcendem o
ponto de vista oncológico, com impacto direto na atuação do cirurgião
plástico quanto aos aspectos que envolvem a reconstrução, tanto no
planejamento quanto suas complicações.
Palavras-chave: Mastectomia subcutânea; Implante mamário; Neoplasias da mama; Complicações pós-operatórias; Fatores de risco; Mamoplastia
ABSTRACT
BACKGROUND: The goal of aesthetic otoplasty is the correction of ear deformities by creating harmonious and symmetrical external ears, without visible scars. Otoplasty techniques based on the excision of postauricular skin are associated with high recurrence rates. Modern otoplasty is based on cartilage-cutting and cartilage-sparing techniques, alone or in combination, which lead to lower recurrence rates. OBJECTIVE: We evaluated the efficacy of otoplasty combined with other techniques in the correction of ear deformities, based on a modified version of the "algorithm for otoplasty at the Craniofacial Center at Texas Children's Hospital". METHODS: Forty patients, who underwent otoplasty for prominent ears in our institution between March and September of 2009, were prospectively assessed. The mastoid-helix distance was measured preoperatively (baseline) and at 1, 3, and 6 months postoperatively. RESULTS: The most common deformities were scaphoconchal angle greater than 90º (51.3%, 41/80 ears) and conchal hypertrophy > 2.5 cm (46.3%, 37/80 ears). Recurrence occurred in 2 (5%) patients and partial stenosis of the ear canal in 1 (2.5%). Significant reductions in the mastoid-helix distance were observed at the three time points compared with baseline (P<0.001); a significant reduction was present in the immediate postoperative period (P<0.001), followed by a small increase 3 months postoperatively (P<0.005), which appeared to stabilize between 3-6 months postoperatively (P=0.520). CONCLUSION: Otoplasty performed according to the modified algorithm resulted in a significant reduction of the mastoid-helix distance, which slightly increased in the early postoperative period, and re-mained unchanged 6 months postoperatively.
Keywords: Otologic surgical procedures. Ear, External. Deformities.
RESUMO
INTRODUÇÃO: O objetivo da otoplastia estética é a correção de deformidades da orelha, criando orelhas externas harmoniosas e simétricas. As técnicas de otoplastia, baseadas na excisão da pele pós-auricular, estão associados com a recorrência elevada. A otoplastia moderna é baseada nas técnicas de ressecção e/ou modelagem da cartilagem, que levam a menores taxas de recorrência. OBJETIVO Foi avaliada a eficácia da otoplastia com técnica combinada na correção de deformidades da orelha, baseado numa versão modificada do "algoritmo para otoplastia", no Centro Craniofacial do Hospital Infantil do Texas". MÉTODO: Quarenta pacientes submetidos à otoplastia por orelhas proeminentes, entre março e setembro de 2009, foram avaliados prospectivamente. A distância mastoide-hélice foi medida no pré-operatório e após 1, 3 e 6 meses após a cirurgia. RESULTADOS: As deformidades mais comuns foram ângulo escafo-conchal maior que 90º (51,3%, 41/80 orelhas) e hipertrofia de concha> 2,5 cm (46,3%, 37/80 orelhas). Reduções significativas na distância mastoide-hélice foram observadas nos três períodos em comparação com os valores basais (P<0,001). Houve uma redução desta medida no período pós-operatório imediato (P<0,001), seguido por um pequeno aumento após três meses da cirurgia (P<0,005) e subsequente tendência de estabilização entre 3-6 meses após a cirurgia (P=0,520). CONCLUSÃO: Otoplastia, realizada de acordo com o algoritmo citado, resultou em redução significativa da distância mastoide-hélice, com ligeira perda desta redução no início do período pós-operatório, e com tendência a manter-se inalterado após 6 meses de pós-operatório.
Palavras-chave: Orelha externa. Otoplastia. Deformidades.
ABSTRACT
BACKGROUND: This study establishes a technique for dissection of the retroglandular space through abdominoplasty by using a lighted retractor for the introduction of silicone gel breast implants. METHODS: A retrospective study was carried out for 44 patients with abdominal flaccidity and hypomastia who underwent breast augmentation through a single-stage abdominoplasty between September 2001 and April 2012. RESULTS: This method enabled improvement of the abdominal contour and breast augmentation through the same incision. The complications observed affected the abdominal area (hematoma, seroma, dehiscence, and hypertrophic scarring) and the breast (capsular contracture and infection). CONCLUSIONS: Breast augmentation through abdominoplasty does not cause scars on the breast or armpit and is a safe and reproducible procedure with a short learning curve. Moreover, it provides satisfactory and long-lasting results.
Keywords: Abdomen/surgery. Plastic surgery/methods. Breast implantation. Breast implants. Mammaplasty.
RESUMO
INTRODUÇÃO: Este trabalho demonstra a técnica de dissecção de espaço retroglandular através da abdominoplastia, com visualização de fibra óptica para inclusão de implantes mamários de silicone gel. MÉTODO: Foram avaliadas, retrospectivamente, 44 pacientes portadoras de flacidez abdominal e hipomastia, submetidas a mastoplastia de aumento através da abdominoplastia em um só estágio, durante o período de setembro de 2001 a abril de 2012. RESULTADOS: A técnica utilizada possibilitou melhora do contorno abdominal e aumento do volume mamário pela mesma incisão. As complicações ocorreram na área abdominal (hematoma, seroma, deiscência e cicatriz hipertrófica) e na região mamária (contratura capsular e infecção). CONCLUSÕES: A técnica de mastoplastia de aumento por via abdominal evita cicatrizes nas mamas ou axilas, é segura, reprodutível, com curva de aprendizado curta, e resultados satisfatórios e duradouros.
Palavras-chave: Abdome/cirurgia. Cirurgia plástica/métodos. Implante mamário. Implantes de mama. Mamoplastia.
All scientific articles published at www.rbcp.org.br are licensed under a Creative Commons license