ISSN Online: 2177-1235 | ISSN Print: 1983-5175

Showing of 1 until 2 from 2 result(s)

Search for : Rosana Cristina Costa Damasio

Ultrasound-Assisted Liposuction - 348 Cases Analyzed

Ruth Graf, André Auersvald, Rosana Cristina Costa Damasio, Luiz Roberto Reis de Araújo, Ronald Rippel, Lincoln Graça Neto, Luiz Henrique Camargo Bigarelli, Cláudio Luciano Franck
Rev. Bras. Cir. Plást. 2002;17(3):37-46 - Articles

PDF Portuguese PDF English

ABSTRACT

The authors report their experience in using ultrasound-assisted liposuction in 348 patients in the period between October 1998 and July 2001. The application of ultrasound brought additional benefits to results, such as improved skin accommodation and the treatment of difficult cases, such as, gynecomasty, dorsum and secondary liposuction. The technique was performed in three stages: super-wet infiltration (l.35:1), followed by ultrasound-assisted liposuction and conventional liposuction. The equipment used was a Lisonix 2000 generator at the setting of 5, that is, 50% of the device's power; which proved to be the setting that causes the least secondary effects, such as tissue fibrosis and seroma. This study also considers the history of ultrasound assisted liposuction and focuses on the physical aspects of ultrasound, with a review on the literature on the use of the ultrasound technique.

Keywords: Liposuction; ultrasound; body contour

 

RESUMO

Os autores mostram a experiência da utilização da lipoaspiração ultra-sônica em 348 pacientes no período de outubro de 1998 a julho de 2001. A aplicação do ultra-som trouxe benefícios adicionais aos resultados, como melhor acomodação da pele e tratamento de áreas difíceis, como ginecomastia, dorso e lipoaspiração secundária. A técnica utilizada em três estágios consistiu de infiltração super-úmida (1,35:1), seguida da lipoaspiração ultra-sônica e lipoaspiração convencional. O equipamento Lisonix 2000 foi utilizado numa amplitude de 5, ou seja, 50% da potência do aparelho, que demonstrou ser a que menor efeito secundário causa, como fibrose tecidual e seroma. São considerados no artigo o histórico da lipoaspiração ultra-sônica e um enfoque na física do ultra-som, com revisão da literatura relacionada à aplicação da técnica ultra-sônica.

Palavras-chave: Lipoaspiração; ultra-sônica; contorno corporal

 

Subfascial Endoscopic Transaxillary Augmentation Mammaplasty

Ruth Maria Graf, Afranio Bernardes, Andre Auersvald, Rosana Cristina Costa Damasio
Rev. Bras. Cir. Plást. 1999;14(2):45-54 - Articles

PDF Portuguese PDF English

ABSTRACT

Videoendoscopy for breast hypoplasia and glabelar frownlines has been used since 1996 in our private clinic. Breast augmentation with "S" shape incision for transaxillary acessis utilized to introduce the implant, in a submuscular or subglandular, and recently (since october 1998) in a subfascial location. From August 1998 through January 1999, 62 patients underwent endoscopics surgeries, forty nine were submuscular, five subglandular and eight subfascial. McGhan® 410, anatomical biodimentional, 155 grams through 235 grams were used. We observed three cases of complications, two of them malpositioning (rotation) needing reoperation and 1 hematoma treated with drainage. Patient satisfaction was high, especially regarding the axillary incision. There have been no capsular contractions to date.

Keywords: Mastoplasty; endoscopy; mammary surgery.

 

RESUMO

No nosso serviço, a prática da cirurgia videoendoscópica começou em 1996, sendo utilizada para tratamento de hipoplasia mamária e de rugas frontais, que seriam as cirurgias videoendoscópicas mamária e facial. Na mamaplastia de aumento foi utilizada a via transaxilar com incisão em forma de "S" para introduzir o implante mamário na posição submuscular ou subglandular e, mais recentemente (outubro de 1998), na posição subfascial. Essa cirurgia foi realizada em 62 pacientes, no período de agosto de 1996 a janeiro de 1999, sendo introduzidas as próteses no espaço submuscular em 49 pacientes, subglandular em 5 pacientes e subfascial em 8 pacientes. O tipo de implante utilizado foi o modelo anatômico 410, biodimensional da McGhan®, com variação de 155 a 235 gramas. Ocorreram complicações em três pacientes, sendo que houve a rotação da prótese com assimetria em duas delas com necessidade de reoperação e, em uma paciente, formou-se um hematoma, que foi resolvido por punção. O grau de satisfação pessoal foi alto, sendo a maior vantagem dessa técnica a ausência de cicatriz nas mamas. Nenhum dos casos até o momento apresentou algum grau de contratura capsular.

Palavras-chave: Mastoplastia; endoscopia; cirurgia mamária.

 

Indexers

Licença Creative Commons All scientific articles published at www.rbcp.org.br are licensed under a Creative Commons license