ISSN Online: 2177-1235 | ISSN Print: 1983-5175
Showing of 1 until 2 from 2 result(s)
Search for : Luiz Henrique Camargo Bigarelli
ABSTRACT
Introduction: Preoperative tests (EPO) aim to detect abnormalities and give greater safety to the procedure. However, the request for these tests is still controversial, either because they do not bring about changes in conduct for the procedure or result in some harm to the patient. The objective is to assess the frequency of EPO requests and abnormalities in aesthetic plastic surgery patients, to verify what these abnormalities are, what preoperative management should be done based on the finding, and to associate the data obtained with the patient's profile and the planned surgery.
Method: Retrospective study evaluating medical records of aesthetic plastic surgery patients who underwent routine EPO in a plastic surgery hospital in 2019.
Results: 978 patients were studied, and 51% had some abnormality in EPO. 93.7% were women, with a mean age of 46.5 years. 12.3 exams were performed per patient, and abnormality was observed in 6.1% of EPO. The exams that had the most abnormalities were the lipidogram (23.8%) and the cardiac evaluation (14.1%). Hypothyroidism was the most common comorbidity (18.4% of patients); 70% of diabetics had a glycemic level above the recommended level. Only 3.4% of the patients suffered a change in preoperative management due to EPO abnormality, and in 57.9% of these cases, the surgery was postponed. Test alterations were more frequent in male patients (p<0.0001).
Conclusion: The performance of routine EPO showed a low frequency of altered exams (3.4%) and implied changes in the preoperative conduct of plastic surgery patients.
Keywords: Diagnostic tests, routine; Reconstructive surgical procedures; Preoperative care; Patient care management; Health care costs.
RESUMO
Introdução: Os exames pré-operatórios (EPO) visam detectar anormalidades e dar maior segurança ao procedimento. No entanto, a solicitação desses exames ainda é controversa, seja por não trazerem mudanças de conduta para o procedimento ou resultar em alguns malefícios para o paciente. O objetivo é avaliar a frequência de solicitações e de anormalidades dos EPO em pacientes de cirurgia plástica estética, verificar quais são estas anormalidades, qual conduta pré-operatória mediante o achado e associar os dados obtidos com o perfil do paciente e cirurgia prevista.
Método: Estudo retrospectivo avaliando prontuários de pacientes de cirurgia plástica estética que realizaram EPO de rotina em um hospital de cirurgia plástica durante o ano de 2019.
Resultados: Foram estudados 978 pacientes e 51% desses apresentaram alguma anormalidade nos EPO. 93,7% eram mulheres, com média de idade 46,5 anos. Foram realizados 12,3 exames por paciente e observada anormalidade em 6,1% dos EPO. Os exames que mais tiveram anormalidades foram o lipidograma (23,8%) e os da avaliação cardíaca (14,1%). Hipotireoidismo foi a comorbidade mais achada (18,4% dos pacientes); 70% dos diabéticos estavam com o nível glicêmico acima do recomendado. Apenas 3,4% dos pacientes sofreram alteração da conduta pré-operatória devido anormalidade dos EPO e em 57,9% desses casos houve adiamento da cirurgia. Alterações de exames foram mais frequentes em pacientes do sexo masculino (p<0,0001).
Conclusão: A realização de EPO de rotina mostrou baixa frequência de exames alterados (3,4%) e implicou em mudanças na conduta pré-operatória em pacientes de cirurgia plástica.
Palavras-chave: Testes diagnósticos de rotina; Procedimentos cirúrgicos reconstrutivos; Cuidados pré-operatórios; Administração dos cuidados ao paciente; Custos de cuidados de saúde
ABSTRACT
The authors report their experience in using ultrasound-assisted liposuction in 348 patients in the period between October 1998 and July 2001. The application of ultrasound brought additional benefits to results, such as improved skin accommodation and the treatment of difficult cases, such as, gynecomasty, dorsum and secondary liposuction. The technique was performed in three stages: super-wet infiltration (l.35:1), followed by ultrasound-assisted liposuction and conventional liposuction. The equipment used was a Lisonix 2000 generator at the setting of 5, that is, 50% of the device's power; which proved to be the setting that causes the least secondary effects, such as tissue fibrosis and seroma. This study also considers the history of ultrasound assisted liposuction and focuses on the physical aspects of ultrasound, with a review on the literature on the use of the ultrasound technique.
Keywords: Liposuction; ultrasound; body contour
RESUMO
Os autores mostram a experiência da utilização da lipoaspiração ultra-sônica em 348 pacientes no período de outubro de 1998 a julho de 2001. A aplicação do ultra-som trouxe benefícios adicionais aos resultados, como melhor acomodação da pele e tratamento de áreas difíceis, como ginecomastia, dorso e lipoaspiração secundária. A técnica utilizada em três estágios consistiu de infiltração super-úmida (1,35:1), seguida da lipoaspiração ultra-sônica e lipoaspiração convencional. O equipamento Lisonix 2000 foi utilizado numa amplitude de 5, ou seja, 50% da potência do aparelho, que demonstrou ser a que menor efeito secundário causa, como fibrose tecidual e seroma. São considerados no artigo o histórico da lipoaspiração ultra-sônica e um enfoque na física do ultra-som, com revisão da literatura relacionada à aplicação da técnica ultra-sônica.
Palavras-chave: Lipoaspiração; ultra-sônica; contorno corporal
All scientific articles published at www.rbcp.org.br are licensed under a Creative Commons license