ISSN Online: 2177-1235 | ISSN Print: 1983-5175
Showing of 1 until 2 from 2 result(s)
Search for : Fraga Luis Fernando Perin
ABSTRACT
INTRODUCTION: Autologous fat graft possesses the desired qualities of a filling material. However, the largest barriers to its further development are unpredictable results and high rate of absorption of the grafted fat over time. The objective is to perform a volumetric assessment of the breasts in patients undergoing fat grafting using pre-operative external expansion (BRAVA®). METHODS: Nineteen patients were operated between March 2012 and June 2015 in the Service of Plastic Surgery, Santa Casa de São Paulo. The parameters evaluated using nuclear magnetic resonance (pre-operatively and 6 months post-operatively) were the following: augmented volume=post-operative volume - pre-operative volume; percentage of augmentation=augmented volume/pre-operative volume x 100; percentage of integration=augmented volume/volume grafted x 100. RESULTS: The average volume of the breasts in the pre- and post-operative periods were 294.73 ml and 458.42 ml, respectively. The average graft volume was 274.4 ml (150-350 ml). The following parameters were assessed: average volume augmentation, 168.42 ml (90-270 ml); average percentage of augmentation, 58.98% (23-90%); and average percentage of integration, 62.36% (30-80%). CONCLUSION: The use of external expansion (BRAVA®) in breasts was effective in increasing the rates of integration of the fat grafts and the overall augmentation in breast volumes.
Keywords: Graft Survival; Tissue expansion devices; Mammoplasty; Autografts.
RESUMO
INTRODUÇÃO: O enxerto autólogo de tecido adiposo exibe qualidades desejáveis para utilização como material de preenchimento. Contudo, a grande barreira para o seu maior desenvolvimento foram os resultados pouco previsíveis e o alto índice de absorção da gordura enxertada ao longo do tempo. O objetivo é realizar avaliação volumétrica das mamas de pacientes submetidas à lipoenxertia com uso de expansão pré-operatória (BRAVA®). MÉTODOS: Foram operadas 19 pacientes no período entre março de 2012 e junho de 2015 na disciplina de Cirurgia Plástica da Santa Casa de São Paulo. Os parâmetros avaliados por ressonância nuclear magnética (pré e 6 meses pós-operatório) foram: Volume Aumentado=Volume Pós-operatório - Volume Pré operatório; Percentual de Aumento=Volume Aumentado/Volume Pré operatório x100; Percentual de Integração=Volume Aumentado/Volume Enxertado x 100. RESULTADOS: O volume médio das mamas no pré-operatório foi de 294,73 ml e de 458,42 ml no pós-operatório. O volume médio de enxerto foi de 274,4 ml (150-350 ml). Em relação aos parâmetros avaliados, o volume médio de aumento foi de 168,42 ml (90-270 ml), o percentual médio de aumento foi de 58,98% (23-90%) e o percentual médio de integração foi de 62,36% (30-80%). CONCLUSÃO: A utilização da expansão externa (BRAVA®) na mama mostrou-se um método efetivo nas taxas de integração do enxerto de gordura, bem como no aumento global do volume mamário.
Palavras-chave: Sobrevivência de enxerto; Dispositivos para expansão de tecidos; Mamoplastia; Autoenxertos.
ABSTRACT
The microsurgical anastomosis technique is practically challenging and requires extensive training, dedication, and time for inexperienced surgeons to perfect. In the present report, we describe an accessible, practical, and simple training model, which involves the use of an abdominal flap obtained from abdominoplasties. The caliber of the superficial epigastric vessels found in the excised abdominal flaps ranged from 1.2 mm to 2.0 mm, depending on the preoperative body mass index of the patient. This flap facilitated the training of microsurgical anastomosis in blood vessels with different calibers. These vessels had a small amount of remnant blood within the lumen, which enabled the testing of the quality and patency of the anastomosis. This training model involving human abdominal vessels allows for a quicker transition to actual operative situations, compared to the use of animal or inanimate models. Moreover, effective practice of dissection and endtoend and endtoside anastomoses using our model helps in the development of skill and surgical dexterity.
Keywords: Anastomosis, surgical. Microsurgery. Abdomen/surgery. Training.
RESUMO
A técnica de anastomose microcirúrgica é desafiadora e requer treinamento extenso, dedicação e tempo. Os autores descrevem um modelo de treinamento acessível, prático e fácil, que utiliza retalho abdominal proveniente de abdominoplastias. O calibre dos vasos epigástricos superficiais encontrados nos retalhos abdominais excisados variou de 1,2 mm a 2 mm, dependendo do índice de massa corporal da paciente no préoperatório. Esse retalho permitiu o treinamento de anastomoses microcirúrgicas em vasos de diferentes calibres. Esses vasos permaneciam com pequena quantidade de sangue em seu lúmen, o que permitia testar a qualidade e a patência das anastomoses. Esse modelo de treinamento em vasos abdominais humanos, quando comparado aos modelos animais ou inanimados, permite transição mais rápida e real aos pacientes. A prática de dissecção e de anastomoses terminoterminais e terminolaterais de uma maneira efetiva e prática aperfeiçoa a destreza cirúrgica.
Palavras-chave: Anastomose cirúrgica. Microcirurgia. Abdome/cirurgia. Capacitação.
All scientific articles published at www.rbcp.org.br are licensed under a Creative Commons license