ISSN Online: 2177-1235 | ISSN Print: 1983-5175
Showing of 1 until 10 from 10 result(s)
Search for : Fernando Serra
RESUMO
Recentemente, com a popularização das diversas técnicas de gluteoplastia e o incremento no número de pacientes procurando este tipo de procedimento, ocorreu um aumento considerável na incidência de complicações envolvendo o implante de próteses glúteas. As complicações mais frequentes são seroma e deiscência de ferida operatória. Infecção superficial ou profunda, hematomas, assimetrias, dor crônica e deslocamento dos implantes glúteos também estão descritas. A falta de familiaridade de uma parte dos cirurgiões plásticos com a gluteoplastia de aumento torna importante a discussão sobre o diagnóstico e tratamento de suas complicações.
Palavras-chave: Gluteoplastia; Implante glúteo; Silicone; Complicações
ABSTRACT
INTRODUCTION: Liposuction is a surgical procedure that was developed approximately 30 years ago by Fournier, Illouz, and others. In 2011, a total of 211,108 liposuction procedures were performed in Brazil versus 325,332 in the United States. Over the years, liposuction performed with the tumescent technique has had a good safety profile. It is also performed by other specialists, including dermatologists, and has been described as an outpatient procedure in public institutions in Brazil. The scarcity of data on the subject has led the Brazilian Society of Plastic Surgery (BSPS) to create a commission composed of 10 full members with the aim of investigating the factors involved in severe liposuction-related complications and death in Brazil. METHODS: An online questionnaire was created using an anonymous link on the BSPS website. The questionnaire was sent to the registered email addresses of 4,441 associate and full members of the BSPS. The first question was about the occurrence of liposuction-related complications. The respondents could only continue to answer the questionnaire if the answer to this question was "yes." In addition to the questionnaire, the BSPS sent letters to the official state and federal institutions in which the case or complication/death-related records and/or deaths as a consequence of liposuction were expected to exist. The significance of the association between death and the various factors was determined using the chi-square test. The significant variables were included in Poisson Regression Models. The significance level was set at 5%. The data were analyzed using STATA software version 10.0. RESULTS: Thromboembolic events, combined surgical procedures, and the facilities where the procedure was performed were risk factors involved in liposuction-related mortality. CONCLUSION: The implementation of programs that aim to standardize liposuction procedures may effectively reduce liposuction-related mortality rates. This study aimed to make a positive educational impact on the development of future safe liposuction protocols.
Keywords: Liposuction; Lipoplasty; Mortality rate; Complications; Survey.
RESUMO
INTRODUÇÃO: A lipoaspiração, procedimento cirúrgico com cerca de 30 anos desde sua sistematização por Fournier, Illouz e outros, atingiu, em 2011, o total de 211.108 cirurgias realizadas no Brasil e 325.332, nos Estados Unidos. Ao longo dos anos, foi reputado como procedimento seguro, baseado em conceitos da técnica tumescente. Realizado também por outras especialidades, já foi descrito como método ambulatorial, inclusive em instituições públicas no Brasil, por dermatologistas. Motivada por essa lacuna de dados, a Sociedade Brasileira de Cirurgia Plástica criou uma comissão composta por dez membros titulares, com o objetivo de realizar uma pesquisa para reconhecer a presença de possíveis fatores envolvidos nas intercorrências graves e nos óbitos, após uma cirurgia de lipoaspiração no Brasil. MÉTODOS: Foi elaborado um questionário on-line através de um link anônimo e disponível para consulta, no site da SBCP. O questionário foi enviado, através dos e-mails de cadastro, para 4.441 membros associados e titulares da SBCP. A primeira questão indagava sobre a ocorrência de intercorrências em lipoaspiração. Somente a resposta positiva era então direcionada ao restante do questionário. Além do questionário, foram enviadas cartas pela SBCP às instituições oficiais estaduais e federais, nas quais prováveis registros de processos ou cadastro de fatos relacionados a intercorrências e/ou óbitos após lipoaspiração poderiam existir. A significância da associação entre óbito e os diversos fatores foi medida com aplicação do teste qui-quadrado. As variáveis significantes foram incluídas em Modelos de Regressão de Poisson. Foi considerado o nível de significância de 5%. Os dados foram analisados com auxílio do programa STATA versão 10.0. RESULTADOS: Fenômenos tromboembólicos, associação de cirurgias e o local de realização da cirurgia demostraram ser fatores de risco envolvidos na mortalidade de lipoaspiração. CONCLUSÃO: Programas visando à normatização na realização das lipoaspirações podem ser eficazes na diminuição da mortalidade em lipoaspiração. Acreditamos que este artigo pode promover um impacto positivo educacional e, futuramente, gerar protocolos de segurança em lipoaspiração.
Palavras-chave: Lipoaspiração; Lipoplastia; Taxa de mortalidade; Complicações; Pesquisa.
ABSTRACT
Introduction: Eyelid ptosis is a common condition in clinical practice for which a complete
evaluation is mandatory. Ptosis is defined when the eyelid margin is 2 mm
below the corneoscleral junction and can be classified as mild, moderate,
and severe. There are numerous repair techniques, and the choice will depend
on the classification of the function of the levator muscle.
Methods: We evaluated prospectively, from March 2013 to May 2015, 14 patients who
underwent surgical treatment of moderate and severe ptosis (n = 21). Several
factors were studied, such as degree of ptosis and function of the eyelid
levator muscle, type of repair technique, and immediate and late
complications.
Results: Fourteen patients (21 eyelids) underwent operation. The etiology was acquired
in 85% of the cases and congenital in 15%. With respect to the degree of
ptosis, 64.3% (n = 9) of the cases were moderate and 35.7% (n = 5) were
severe. With respect to the muscle function of the levator, good, moderate,
and poor functions were observed in 28.5% (n = 4), 28.5% (n = 4), and 43% (n
= 6) of the cases, respectively. With regard to complications, 2 cases of
conjunctival hyperemia and one case of edema were observed. We obtained a
high satisfaction rate of 85.7% (n = 12), with low complication rates.
Conclusion: Eyelid ptosis is a common presentation in clinical practice and requires on
the part of the surgeon a detailed anatomical knowledge of the delicate
structure of the eyelid and its pathophysiology. A complete evaluation of
these patients is mandatory for the employment of the most appropriate
treatment.
Keywords: Blepharoptosis; Blepharophimosis; Myasthenia gravis; Fascia lata; Eyelid diseases
RESUMO
Introdução: A ptose palpebral é uma afecção comum na prática clínica na qual uma perfeita
avaliação torna-se mandatória. Definimos ptose quando a margem palpebral
encontra-se abaixo de 2 mm da junção corneoescleral e pode ser classificada
em leve, moderada e grave. Existem inúmeras técnicas de reparo e a escolha
dependerá da classificação da função do músculo levantador.
Métodos: Foram analisados de forma prospectiva, no período de março de 2013 a maio de
2015, quatorze (n = 14) pacientes submetidos ao tratamento cirúrgico de
ptose palpebral moderada e grave (n = 21). Inúmeros fatores foram estudados,
tais como grau de ptose e função do músculo elevador da pálpebra, tipo de
técnica de reparo, complicações imediatas e tardias, etc.
Resultados: Quatorze pacientes foram opera-dos, totalizando 21 pálpebras, sendo que, 85%
foram de etiologia adquirida e 15% congênita. Com relação ao grau de ptose,
64,3% (n = 9) foram moderadas e 35,7% (n = 5) graves. No que tange à função
do músculo levantador, encontramos função boa 28,5% (n = 4), moderada 28,5%
(n = 4) e pobre 43% (n = 6). Em relação às com-plicações, 2 casos de
hiperemia conjutival e um caso de edema. Obtivemos um alto índice de
satisfação com 85,7% (n = 12), com baixas taxas de complicações.
Conclusão: A ptose palpebral é uma enfer-midade comum na prática clínica e exige por
parte do cirurgião um perfeito conhecimento anatômico da delicada estrutura
palpebral e também de sua fisiopatologia. Uma perfeita avaliação desse
paciente torna-se mandatória para o emprego do tratamento mais adequado.
Palavras-chave: Blefaroptose; Blefarofimose; Miastenia gravis; Fascia lata; Doenças palpebrais
ABSTRACT
BACKGROUND: Silicone implants are used in several regions of the body. In women, sagging of the triceps muscle is a major concern. Meanwhile, men consider biceps and triceps hypertrophy to be a symbol of masculinity and beauty. Here, we describe a relatively simple and reproducible procedure used for esthetic purposes to increase arm circumference or correct mild to moderately sagging skin using gel silicone implants and elastomer. METHODS: Thirty-two patients were selected and operated on. Two to four implants per arm were introduced. RESULTS: The esthetics of the arms improved significantly in the studied patients, with a satisfaction rate exceeding 90%. The procedure improved static evaluation and arm movement, which were the major complaints of majority of the female patients. CONCLUSIONS: The surgical technique presented for augmentation brachioplasty is safe and reproducible, and should be considered by plastic surgeons in an attempt to achieve better results with smaller incisions.
Keywords: Arm/surgery. Silicone gels. Silicone elastomers. Prostheses and implants.
RESUMO
INTRODUÇÃO: Os implantes de silicone são utilizados em diversas regiões do corpo. Em mulheres, a flacidez da musculatura do tríceps constitui um dos grandes incômodos; por outro lado, em homens, a hipertrofia da região do bíceps e tríceps é sinal de masculinidade e beleza. O objetivo deste trabalho é descrever uma técnica relativamente simples e reprodutível para aumento da circunferência do braço ou para correção de flacidez de grau leve a moderado com fins estéticos, com uso de implantes de silicone gel e elastômero. MÉTODO: Foram selecionados e operados 32 pacientes, com a introdução de no mínimo 2 implantes e no máximo 4 implantes por braço. RESULTADOS: Houve melhora significativa da estética dos braços dos pacientes estudados, com índice de satisfação superior a 90%. A melhora foi sentida na avaliação estática e em movimento do braço, grande queixa da maioria de pacientes do sexo feminino. CONCLUSÕES: A técnica cirúrgica apresentada para braquioplastia de aumento é segura e reprodutível, sendo mais uma opção no arsenal terapêutico do cirurgião plástico em sua busca por resultados melhores, com incisões menores.
Palavras-chave: Braço/cirurgia. Géis de silicone. Elastômeros de silicone. Próteses e implantes.
All scientific articles published at www.rbcp.org.br are licensed under a Creative Commons license