ISSN Online: 2177-1235 | ISSN Print: 1983-5175

Showing of 1 until 2 from 2 result(s)

Search for : Adriana Yuriko Koga

Evaluation of blood biomarkers in rats submitted to nanotextured and polyurethane foam-coated silicone implants

Eduardo Nascimento Silva; Gisela Hobson Pontes; Francine Marques Bandeira; Adriana Yuriko Koga; Lydia Masako Ferreira; Leandro Cavalcante Lipinski
Rev. Bras. Cir. Plást. 2021;36(3):249-256 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: In recent decades, there has been a great evolution in breast implants' lining surface, which has resulted in decreased complications. In the postoperative period, the inflammation is constant and can be evaluated by the blood count, as it is a fast, inexpensive, and highly available examination. The present study evaluates blood biomarkers in rats submitted to the placement of nanotextured silicone implants and implants coated with polyurethane foam.
Methods: 60 Wistar rats were used divided into two groups for nanotextured mini-implants and others mini-implants coated with polyurethane foam, subdivided into subgroups according to the animals' euthanasia in the 30, 60, and 90 days. At the time of euthanasia, blood samples were obtained by cardiac puncture and the blood count was analyzed.
Results: Hemoglobin, hematocrit, mean corpuscular hemoglobin, leukocytes, neutrophils, lymphocytes, and platelets had very similar results in all subgroups evaluated (30, 60, and 90 days). However, when the different subgroups were compared within each group, statistically significant results were obtained in the mean corpuscular hemoglobin (nanotextured p=0.032 and polyurethane p=0.007) and leukocytes (nanotextured p=0.038 and polyurethane p=0.034). Changes in postoperative blood biomarkers were hypochromic anemia, normal leukocyte count, neutrophilia, lymphopenia, and thrombocytopenia.
Conclusion: After the placement of mini-silicone implants, the rats of both groups evolved with hypochromic anemia, normal leukocyte count at the expense of neutrophilia and lymphopenia, and thrombocytopenia.

Keywords: Biomarkers; Blood cell count; Rats; Breast implant; Mammoplasty.

 

RESUMO

Introdução: Nas últimas décadas houve uma grande evolução na superfície de revestimento dos implantes mamários, o que resultou na diminuição das complicações. No pós-operatório a inflamação é uma constante e pode ser avaliada pelo hemograma, pois é um exame rápido, barato e com alta disponibilidade. O presente estudo tem como objetivo avaliar os biomarcadores sanguíneos em ratas submetidas à colocação de mini-implantes de silicone nanotexturizados e revestidos por espuma de poliuretano.
Métodos: Foram utilizadas 60 ratas Wistar divididas em dois grupos para utilização de mini-implantes nanotexturizados e revestidos com espuma de poliuretano, subdivididos em subgrupos de acordo com a eutanásia dos animais nos 30, 60 e 90 dias. No momento da eutanásia, as amostras de sangue foram obtidas por punção cardíaca e foi analisado o hemograma.
Resultados: A hemoglobina, o hematócrito, a hemoglobina corpuscular média, os leucócitos, os neutrófilos, os linfócitos e as plaquetas tiveram os resultados muito semelhantes em todos os subgrupos avaliados (30, 60 e 90 dias). Entretanto, quando os diferentes subgrupos foram comparados entre si dentro de cada grupo, obteve-se resultados estatisticamente significantes na hemoglobina corpuscular média (nanotexturizado p=0,032 e poliuretano p=0,007) e nos leucócitos (nanotexturizado p=0,038 e poliuretano p=0,034). Sobre as alterações dos biomarcadores sanguíneos no pós-operatório encontrou-se anemia hipocrômica, contagem de leucócitos normais, neutrofilia, linfopenia e trombocitopenia.
Conclusão: Após a colocação de mini-implantes de silicone, as ratas de ambos os grupos evoluíram com anemia hipocrômica, contagem de leucócitos normais às custas de neutrofilia e linfopenia, e trombocitopenia.

Palavras-chave: Biomarcadores; Contagem de células sanguíneas; Ratos; Implante de mama; Mamoplastia

 

Evaluation of protein adsorption in rats submitted to nanotextured and polyurethane foam-coated silicone mini-implants

Eduardo Nascimento Silva; Gisela Hobson Pontes; Bárbara Zanon da Luz; Adriana Yuriko Koga; Lydia Masako Ferreira; Leandro Cavalcante Lipinski
Rev. Bras. Cir. Plást. 2021;36(3):257-262 - Original Article

PDF Portuguese PDF English

ABSTRACT

Introduction: The control of protein absorption is necessary to define biomaterials' properties and their specific uses. Blood plasma contains several different proteins, including fibrinogen, which plays an important role in cell adhesion and biocompatibility results in implants. This study's objectives were to evaluate in the laboratory rats subjected to the placement of nano-textured silicone mini-implants and polyurethane foam-coated mini-implants based on the measurement of serum fibrinogen and plasma proteins.
Methods: Sixty albino rats were used, divided into two groups of 30 animals for each type of silicone mini-implant (nanotextured and polyurethane foam) and subdivided into three subgroups, according to the animals' euthanasia time (30, 60 and 90 days). The mini-implants were inserted in the animals' backs below the Panniculus carnosus. At the time of euthanasia, blood samples were obtained by cardiac puncture. The thermal precipitation technique was used to determine total and serum plasma proteins, and the difference between the latter two obtained the fibrinogen value.
Results: When the groups were compared, it was observed that the nanotextured group presented a higher amount of fibrinogen and plasma protein in the 90-day subgroup, with statistical significance (p=0.004). When comparing the subgroups among themselves, a significant difference was evidenced (p<0.001).
Conclusion: The nanotextured miniimplants showed a lower protein absorption concerning polyurethane foam-coated implants in the 90-day subgroup.

Keywords: Blood proteins; Experimental implants; Breast implants; Mammoplasty; Rats.

 

RESUMO

Introdução: O controle da absorção de proteínas é necessário para a definição das propriedades dos biomateriais e de seus usos específicos. O plasma sanguíneo contém diversas proteínas diferentes, dentre elas o fibrinogênio, que apresenta importante papel na adesão celular e nos resultados de biocompatibilidade em implantes. Os objetivos deste estudo foram avaliar laboratorialmente as ratas submetidas à colocação de mini-implantes de silicone nanotexturizados e revestidos por espuma de poliuretano a partir da aferição do fibrinogênio sérico e mensuração da proteína plasmática.
Métodos: Foram utilizadas 60 ratas albinas, divididas em dois grupos de 30 animais para cada tipo de mini-implante de silicone (nanotexturizado e espuma de poliuretano) e subdivididas em 3 subgrupos, conforme o tempo de eutanásia dos animais (30, 60 e 90 dias). Os mini-implantes foram inseridos no dorso dos animais abaixo do Panniculus carnosus. No momento das eutanásias, amostras de sangue foram obtidas por punção cardíaca. Utilizou-se a técnica de precipitação térmica para determinação das proteínas plasmáticas total e sérica, e o valor do fibrinogênio foi obtido mediante a diferença entre estas duas últimas.
Resultados: Quando comparados os grupos entre si, observou-se que o grupo nanotexturizado apresentou uma maior quantidade de fibrinogênio e da proteína plasmática no subgrupo de 90 dias, com significância estatística (p=0,004). Ao comparar os subgrupos entre si, em ambos os grupos, evidenciou-se uma diferença significativa (p<0,001).
Conclusão: Os mini-implantes nanotexturizados mostraram uma menor absorção de proteínas em relação aos implantes revestidos pela espuma de poliuretano, no subgrupo de 90 dias.

Palavras-chave: Proteínas sanguíneas; Implantes experimentais; Implantes de mama; Mamoplastia; Ratos

 

Indexers

Licença Creative Commons All scientific articles published at www.rbcp.org.br are licensed under a Creative Commons license